03. 07. 2019 - Řisuty

CTU portable rainfall simulator

Katedra hydromeliorací a krajinného inženýrství, Fakulta stavební ČVUT v Praze
Zdroj financování: Glyfosáty Erosion-3D


dry

precipitation start: 11:20

#239

cultivated fallow

Exp. plot:
#42
Zal.:
03.07.2019
Plot inclination [%]:
9%
Note:
surface runoff not initiated
Precipitation intensity:
60.0 mm.h-1
Initial moisture:
17.0 %V
Organic carbon soil sample
2 (assigned by necessity)
Bulk density soil sample
48 (assigned by similarity)
Soil texture sample
39 (direct measurement)
Canopy cover:
#1432 0.0 %
#674

precipitation

#916

set value

#1979

soil moisture

dry

very wet

precipitation start: 12:35

#240

cultivated fallow

Exp. plot:
#42
Zal.:
03.07.2019
Plot inclination [%]:
9%
delay till the surface runoff:
00:05:00
Precipitation intensity:
60.0 mm.h-1
Initial moisture:
42.0 %V
Organic carbon soil sample
2 (assigned by necessity)
Bulk density soil sample
49 (assigned by similarity)
Soil texture sample
39 (direct measurement)
Canopy cover:
#1432 0.0 %
#675

precipitation

#917

set value

#1306

surface run-off

#1736

raw data

#1307

sediment load

#1737

raw data

#1738

derived data

#1980

soil moisture

very wet